Screw-in connection in-line Thermal Mass Flowmeters

TGF600 Inline Thermal Gas Flowmeters
TGF600 Inline Thermal Gas Flowmeters with more rugged design to adapt to harsh industrial applications. It implements COMATE’s latest sensor filming technology and high sensitivity sensors to ensure a stable measurement at very low flow rate down to 0.3Nm/s.
Special features:
- 100:1 turndown, lower limit to 0.3Nm/s support from 1”~80”pipe
- Temperature range up to 450 °C
- Depth scale for precise installation
- Insertion type to 16bar, special version up to 63 bar
- No moving parts, industrial sensor more robust and easy to clean
- Unique anti-ejection densign support install and remove without stop the line
- IP 67 protection.Robust water-proof housing for the indoor/outdoor area
Application:
- Compressed air, Natural gas, biogas, Oxygen, Argon, Hydrogen, special area
- Coal, power, Incineration, Landfill gas, Petrochemical industry and gas measurement in Heating supply system
- Flare gas, etc high temperature gas measurement
Inline type can be installed/removed without stopping the line
Can be used on pipelines in difference shape
Minimum flow rate down to 0.3m/s, 1:100 super wide turndown ratio
No moving part, almost no pressure loss
Direct mass flow measurement, do not require temperature or pressure compensation
Isolated design for electrical parts to eliminate interference
Optimized power efficiency design, supper low power consumption down to 60mA@24VDC
Adapted to any power source
2 lines LCD display with unit displaying
Standard output is pulse and RS485, Hart@4~20mA and 4~20mA is available
Metric/British Unit selectable
Password protecting function and self-diagnose function
TGF600 Series inline thermal gas flowmeters measures the gas mass flow base on thermal dispersion theory. It combines COMATE’s advanced technology on transmitter, sensor, filming and calibration, can provide stable and accurate measurement even under harsh industrial applications and require very less maintaining.
- Insertion Type
The insertion type thermal mass flowmeters can be installed and maintained online.
- In-line Type
The in-line type thermal mass flow meters is delivered along with a pipe which has a same inner diameters as the pipe in field.
The flanges meet ANSI,DIN or JIS standard.
- Specifications
TGF600- | Insertion type | In-line type | ||
Media Compatibility | Air, Nitrogen,O2,CO2,Argon,CH4, Natural gas, biogas, and almost all dry and clean air | |||
Pipe diameter | DN25~6000mm | DN15~300mm | ||
Flow velocity range | 0.3~30Nm/s or 0.6~60Nm/s or 0.9~90Nm/s or 1.2~120Nm/s | |||
Accuracy | 1.5% RD+ ±1.5% FS | |||
Temperature of medium | -40~+150°c, -40~+250°C,-40~+450°C | |||
Pressure of medium | 1.6MPa/2.5/4.0/6.3 | 4.0Mpa | ||
Power supply | AC85~265V or DC13.5~42V | |||
Response time | 1 second | |||
Output | Frequency + pulse + 4~20Ma as standard | |||
Communication | RS~485 as standard , 4~20mA@HART as optional | |||
Date displayed | Mass flow, Volume flow in normal condition | |||
Total flow , Temperature of medium. Velocity | ||||
Ingress protection grade | IP65 (GB China), IP67(GB China) |
Model | Basic Model | TGF600- | D | N | 1 | T | 1 | 1 | Q | C | 8 | 1 | |
Process Connection | Flanged in-line | F | |||||||||||
Insertion (NPT 1”) | C | ||||||||||||
Insertion (NPT 1”)(with anti-ejection design) | D | ||||||||||||
Insertion (with flange) | G | ||||||||||||
Medium temp range | <150°C | N | |||||||||||
<250°C | Q | ||||||||||||
<450°C(recommend by remote display) | H | ||||||||||||
Probe Length | 290mm (DN25~DN150) | 1 | Standard | ||||||||||
440mm (DN25~DN500) | 2 | Standard | |||||||||||
690mm(DN25~DN100) | 3 | ||||||||||||
1000mm(DN25~DN1500) | 4 | ||||||||||||
1500mm(DN25~DN2200) | 5 | ||||||||||||
Transmitter | Integral | T | |||||||||||
Remote | R | ||||||||||||
Material | OCr18Ni9(304) | 1 | |||||||||||
316 | 2 | ||||||||||||
Pressure Rating | 1.6 Mpa | 1 | |||||||||||
2.5 Mpa | 2 | ||||||||||||
4.0 Mpa | 3 | ||||||||||||
6.3 Mpa | 4 | ||||||||||||
Flange Standard | JIS | A | |||||||||||
GB China | B | ||||||||||||
ANSI | C | ||||||||||||
Q(insertion type) | Q | ||||||||||||
Enclosure | Comate blue enclosure | C | |||||||||||
Transmitte | pulse/frequency + 4~20mA@HART | 7 | |||||||||||
pulse/frequency + 4~20mA + RS485 | 8 | ||||||||||||
Power supply | 13.5~42VDC | 1 | |||||||||||
85~265VAC 50/60Hz | 2 | ||||||||||||
Pipe size | please use 3 digit pipe size, such as DN50=050, DN300=300 | XXX |